Analysis and discrimination of colored pressure sensitive tape backing by microspectrophotometry
|
Susan Gross, Joshua Jorstad
|
Colored Tape Backing, Microspectrophotometry, Duct Tape, Electrical Tape
|
2019
|
December
|
9-1
|
Calcium oxalate crystal identification in kidney tissue
|
Larry Peterson
|
Ethylene glycol, kidney tissue, calcium oxalate crystals, refractive index, Fourier- transform infrared microspectroscopy (micro-FTIR)
|
2019
|
December
|
9-1
|
Trace Isotope Analysis of Dental Enamel for the Micro Regional Geological Attribution of Human Remains in Virginia
|
Nicole Palmer, Robert Stein, Qin Wang, Scott Gronert, Tal Simmons
|
human identification, trace isotopes, dental enamel, Virginia, geolocation
|
2019
|
December
|
9-1
|
Time and temperature dependent analysis of bleach degradation residues on textile fabrics by presumptive chemical analysis and ion chromatography-mass spectrometry
|
Mark LaVigne, Joseph J. Cavaleri, Katherine Roberts
|
Bleach Degradation, Diphenylamine, Ion-Chromatography Mass-Spectrometry, Textile Fabric, Storage Conditions, Orthotolidine, KI-Starch Paper
|
2019
|
December
|
9-1
|
Little Variation Exists Between Laboratory Procedures for the Microscopical Examination of Human Hair
|
Nancy E. Murphy, Amy Reynolds, Adam B. Hall
|
Trace Evidence, Hair Analysis, Microscopical Hair Examination
|
2018
|
November
|
8-1
|
Detection of Bullet v. Nail Damage to Textile Fabrics Using Polarized Light Microscopy
|
Katherine A. Roberts, Gregory Hogrebe, Galyn Fischer, Amanda R. Davis
|
Textile Fabrics, Ductile Fracture, Bullet and Nail Hole Damage, Fiber-end Deformation, Polarized Light Microscopy
|
2018
|
November
|
8-1
|
Discrimination Power of Automotive Paint Comparisons using a Paint Analytical Scheme
|
Amy Reynolds, Kevin Roberts, Alex Thompson, Emily Runt
|
Forensic Science, Trace Evidence, Automotive Paint, Fourier Transform Infrared Spectroscopy, Comparison Microscope, Paint Analysis
|
2018
|
November
|
8-1
|
Study of Transfer and Persistence of Glass in a Mock Kidnapping Case
|
Katrina Rupert, Mandy Ho, Tatiana Trejos
|
Glass Evidence, Glass Persistence, Glass Transfer, Trace Evidence, Vehicle Glass
|
2018
|
November
|
8-1
|
Variability of Refractive Index and Thickness of Tempered Glass throughout an Automotive Window
|
Michael Trimpe, Josi Sammarco
|
Glass, Refractive index, Thickness, Tempered, Automotive window, Variation
|
2017
|
March
|
7-1
|
Evaluation of Refractive Index Values for Permount®
|
Larry Peterson
|
Permount®, Refractive Index
|
2017
|
March
|
7-1
|
The Differences Between Refractive Index Measurements of the External Surface and Bulk Area of Container Glass
|
Joseph Insana, Patrick Buzzini
|
forensic science, trace evidence, glass evidence, container glass, sampling, refractive index measurement, glass refractive index measurement (GRIM), phase contrast microscopy (PCM), filing of glass (FoG) methodforensic science, trace evidence, glass evidence, container glass, sampling, refractive index measurement, glass refractive index measurement (GRIM), phase contrast microscopy (PCM), filing of glass (FoG) method
|
2017
|
March
|
7-1
|
Differential Sampling of Contact Surfaces of Footwear to Separate Fractions of Loosely, Moderately and Tightly Held Particles
|
David A. Stoney, Paul L. Stoney
|
Differential Sampling, Footwear, Contact Surfaces, Particles
|
2017
|
March
|
7-1
|
Evaluation of Duct Tape Physical Characteristics: Part I - Within-Roll Variability
|
Kiersten LaPorte, Robyn Weimer
|
forensic science, trace evidence, duct tape, within-roll variability, physical characteristics
|
2017
|
March
|
7-1
|
Identification of Modern Automotive Paint Systems using Paint Data Query (PDQ): A Collaborative Study
|
Tamara Hodgins, Andrew Ho, Mark Sandercock
|
Automotive Paint, Paint Database, Paint Data Query, PDQ, Infrared Spectroscopy, FTIR, Collaborative Study
|
2015
|
December
|
6-3
|
The Prevalence of Original Equipment Manufacturer (OEM) Factory Repairs in Automotive Paint Samples
|
Diana M. Wright, Andria H. Mehltretter
|
OEM Factory Repairs, Paint Data Query, Interpretation, FTIR, Reference Collections
|
2015
|
December
|
6-3
|
The Physical and Chemical Characterization of Multipurpose Architectural Paint
|
Erica Dolak, Robyn Weimer
|
Paint, Architectural Paint, Multipurpose, Self-priming, Discrimination Power, Analytical Scheme
|
2015
|
December
|
6-3
|
Changes Observed in Human Head Hairs Exposed to Heat
|
Katherine Igowsky, Elizabeth Pangerl
|
Hair, Burnt Hair, Heat Exposure, Hair Exposed to Heat, Forensic Hair Examinations, Microscopic, Hair Characteristics, Arson
|
2015
|
July
|
6-2
|
Evaluation of Automotive Lenses for Forensic Applications by FTIR, PGC, and Raman Spectroscopy
|
Susan T. Gross, Robert Duevel, Jeffrey Wilson, José R. Almirall
|
Forensic Science, Plastics, Taillights, Automotive Lenses
|
2015
|
July
|
6-2
|
Seeing Color: Practical Methods in Pigment Microscopy
|
Christopher S. Palenik, Skip Palenik
|
Pigments, Paints, Fibers, Cosmetics, Forensic, Trace Evidence, Automotive, Architectural, Cross Sections, Smears, Scanning Electron Microscopy (SEM), Polarized Light Microscopy (PLM), Transmission Electron Microscopy (TEM)
|
2015
|
July
|
6-2
|
The Effect of Pigment Type on Pigment Variation due to Differential Mixing in Spray Paints
|
Kris M. Gates
|
Paint, Spray Paint, FT-IR, Pigments, Heterogeneity, Sublimation
|
2015
|
July
|
6-2
|
Flexible Sealants – An Analysis
|
Steven Stone
|
Flexible Sealants, IR, SEM, Py-GC-MS, PLM
|
2015
|
January
|
6-1
|
Intra-Roll and Intra-Jumbo Roll Variation of Duct Tapes
|
Andria H. Mehltretter, Diana M. Wright, Joshua R. Dettman, Michael A. Smith
|
Duct Tape, Variation, Stereomicroscopy, Scrim Count, Width, Thickness, Fourier Transform Infrared Spectroscopy, Statistical Analysis, Jumbo Roll
|
2015
|
January
|
6-1
|
Forensic Fiber Examination Guidelines: Fabric and Cordage
|
SWGMAT
|
None
|
2015
|
January
|
6-1
|
Forensic Fiber Examination Guidelines: Infrared Analysis of Textile Fibers
|
SWGMAT
|
None
|
2015
|
January
|
6-1
|
Plumbum Microraptus: Definitive Microscopic Indicators of a Bullet Hole in a Synthetic Fabric
|
Christopher S. Palenik, Skip Palenik, Peter Diaczuk
|
Ammunition, Backscattered Electron Imaging, Bullets, Energy-Dispersive X-ray Spectroscopy, Fabrics, Fibers, Firearms, Forensic Science, Fourier Transform Infrared Microspectroscopy, Lead, Primer Gunshot Residue, Polarized Light Microscopy, Secondary Electron Imaging, Scanning Electron Microscopy
|
2015
|
January
|
6-1
|
Comparison of Nylon, Polyester, and Olefin Fibers using FTIR and Melting Point Analysis
|
Anne E. Kisler-Rao
|
Fiber, Nylon, Polyester, Olefin, FTIR, Melting Point
|
2015
|
January
|
6-1
|
Differentiation between Lip Cosmetics Using Raman Spectroscopy
|
P. Gardner, M.F. Bertino, Robyn Weimer
|
Cosmetics, Lip Gloss, Lip Balm, Raman
|
2015
|
January
|
6-1
|
Synthetic Wig Fibers: Analysis & Differentiation from Human Hairs
|
Holly Long, Sarah Walbridge-Jones, Kacie Lundgren
|
Wigs, Wig Fibers, Hairs, MSP, FTIR, Cross-sections, Scale Casts, PLM, Microscopy
|
2014
|
January
|
5-1
|
Standard Guide for Using Pyrolysis Gas Chromatography and Pyrolysis Gas Chromatography-Mass Spectrometry in Forensic Paint Examinations
|
SWGMAT
|
None
|
2014
|
January
|
5-1
|
Guideline for Assessing Physical Characteristics in Forensic Tape Examinations
|
SWGMAT
|
None
|
2014
|
January
|
5-1
|
Standard Guide for Using Pyrolysis Gas Chromatography and Pyrolysis Gas Chromatography/Mass Spectrometry in Forensic Tape Examinations
|
SWGMAT
|
None
|
2014
|
January
|
5-1
|
Plumbum Microraptus: Definitive Microscopic Indicators of a Bullet Hole in a Synthetic Fabric
|
Christopher S. Palenik, Skip Palenik, Peter Diaczuk
|
Ammunition, Backscattered Electron Imaging, Bullets, Energy-Dispersive X-ray Spectroscopy, Fabrics, Fibers, Firearms, Forensic Science, Fourier Transform Infrared Microspectroscopy, Lead, Primer Gunshot Residue, Polarized Light Microscopy, Secondary Electron Imaging, Scanning Electron Microscopy
|
2013
|
August
|
4-2
|
The Evidential Value of Fibers Used in Hi-Vis Workwear
|
T. Coyle, C. Shaw, L. Stevens
|
Hi-Vis, Fiber, Evidential Value, Polyester
|
2013
|
August
|
4-2
|
Glycol Ethers: A New Category of Oxygenated Solvents Encountered in Fire Debris Samples
|
Troy Ernst, Kevin Streeter
|
Fire Debris, Oxygenated Solvents, Glycol Ethers, DOWANOL, Scented Oils, Air Fresheners, GC/MS
|
2013
|
August
|
4-2
|
Measurement and Variation of UV Absorbers within Multi-Year Samples of Automotive Clear Coat Paint
|
Steven Stone, Margaret Barber, Ronald Wojciechowski, Paul Martin
|
None
|
2013
|
January
|
4-1
|
Duct Tape Sourcing Examinations: Developing Investigative Leads using Multiple Resources
|
Diana M. Wright, Andria H. Mehltretter
|
Duct Tapes, Sourcing, FTIR, SEM/EDS, XRD, Py-GC/MS, Reference Collections
|
2013
|
January
|
4-1
|
A Method for Isolating Very Small Particles from Plastic Explosive Samples
|
Andrew M. Bowen
|
Composition C4, Dust, Explosives, Forensic Investigation, Plastic Explosives, Polarized Light Microscopy (PLM), Provenance, Scanning Electron Microscope-Energy Dispersive Spectroscopy (SEM/EDS), Small Particles, X-ray Diffraction (XRD)
|
2013
|
January
|
4-1
|
Analysis of Bicomponent Fibers Using Confocal Raman Mapping
|
Robyn Weimer, Jennifer Clary, Robert Heintz, Mark Wall
|
None
|
2012
|
August
|
3-1
|
Chemical Properties of Selected Plastic-Tipped Bullets
|
Melisa C. Thompson, Cady A. Lancaster, Michele G. Banta, Crystal N. Hart, Michael D. Scanlan, Edgard O. Espinoza
|
Plastic-tipped Bullets, Ballistic-tip Ammo, FTIR, XRF, Discriminate Analysis
|
2012
|
August
|
3-1
|
Forensic Analysis and Discrimination of Duct Tapes
|
Andria H. Mehltretter, Maureen J. Bradley
|
Forensic Science, Trace Evidence, Duct Tape, Discrimination, Stereomicroscopy, Fourier Transform Infrared Spectroscopy, X-ray Diffractometry, Scanning Electron Microscopy / Energy Dispersive Spectroscopy
|
2012
|
August
|
3-1
|
Guideline for Assessing Physical Characteristics in Forensic Tape Examinations
|
SWGMAT
|
None
|
2011
|
December
|
2-1
|
Discrimination of Flat (Sheet) Glass Specimens Having Similar Refractive Indices Using Micro X-Ray Fluorescence Spectrometry
|
Scott Ryland
|
Forensic, Glass Comparisons, Discrimination Study, X-ray Fluorescence Spectrometry
|
2011
|
December
|
2-1
|
Particle Combination Analysis for Predictive Source Attribution: Tracing a Shipment of Contraband Ivory
|
David A. Stoney, Andrew M. Bowen, Vaughn M. Bryant, Emily A. Caven, Matthew T. Cimino, Paul L. Stoney
|
None
|
2011
|
December
|
2-1
|
Guideline for Using Fourier Transform Infrared Spectroscopy in Forensic Tape Examinations
|
SWGMAT
|
None
|
2011
|
December
|
2-1
|
Guideline for Using Light Microscopy in Forensic Examinations of Tape Components
|
SWGMAT
|
None
|
2011
|
December
|
2-1
|
Guideline for Using Scanning Electron Microscopy/Energy Dispersive X-ray Spectroscopy in Forensic Tape Examinations
|
SWGMAT
|
None
|
2011
|
December
|
2-1
|
Guideline for Forensic Examination of Pressure Sensitive Tapes
|
SWGMAT
|
None
|
2011
|
December
|
2-1
|
Standard Guide for Using Infrared Spectroscopy in Forensic Paint Examinations
|
SWGMAT
|
None
|
2011
|
December
|
2-1
|
Case Study: Expectations and Interpretations of an Alternate Known Fiber Sample
|
Michael J. Bertocchi
|
Fiber Comparison, Alternate Known Sample, Microspectrophotometry (MSP)
|
2024
|
February
|
13-1
|
A Low-Cost Fiber Optic Visible Microspectrometer for the Small Forensic Science Laboratory
|
Thomas A. Kubic, Mircea A. Comanescu, Tiffany J. Millett
|
microspectrophotometer, forensics, forensic science, criminalistics, fibers, glass, polarized light, microscopy, color, metamerism
|
2024
|
February
|
13-1
|